title: SCS-1 Specifications
description: Specifications for Conserv SCS-1 Sensor
---

[Skip to content](https://support.conserv.io/knowledge/scs-1-specifications#main-content)

English

Show submenu for translations

[Contact us](https://support.conserv.io/knowledge/kb-tickets/new?hsLang=en)

[![Cnsrv\_wmM\_mix\_rgb - MEDIUM-1.png\]](https://support.conserv.io/hs-fs/hubfs/Cnsrv_wmM_mix_rgb%20-%20MEDIUM-1.png?height=40&name=Cnsrv_wmM_mix_rgb%20-%20MEDIUM-1.png)](https://conserv.io/)

- [Support](https://support.conserv.io/knowledge)
- [Blog](https://support.conserv.io/blog)

Open main navigation

Close main navigation

- [Support](https://support.conserv.io/knowledge)
- [Blog](https://support.conserv.io/blog)
- English
  
  Show submenu for translations
- [Contact us](https://support.conserv.io/knowledge/kb-tickets/new)
- [Contact Us](https://support.conserv.io/knowledge/kb-tickets/new)

[Contact Us](https://support.conserv.io/knowledge/kb-tickets/new?hsLang=en)

 How can we help you?

- There are no suggestions because the search field is empty.

1. [Help center](https://support.conserv.io/knowledge?hsLang=en)
2. [Technical Details and Specifications](https://support.conserv.io/knowledge/technical-details-and-specifications?hsLang=en)
3. [Sensor Specifications](https://support.conserv.io/knowledge/technical-details-and-specifications?hsLang=en#sensor-specifications)

# SCS-1 Specifications

## Specifications for Conserv SCS-1 Sensor

Conserv's SCS-1 Smart Collection Sensor is designed specifically for collection care use cases.  It measures temperature, humidity, visible light levels, and movement. This device has a [Texas Instruments HDC2080 sensor](https://www.ti.com/product/HDC2080).

**Important (as of November 2023)**

The [SCS-3](https://support.conserv.io/knowledge/scs-3-specifications?hsLang=en) is the latest model of the Conserv Smart Collection Sensor. It is the version of the sensor you will get if you are a new customer or if you are renewing your subscription. [SCS-1](https://support.conserv.io/knowledge/scs-1-specifications) and [SCS-1 v.2](https://support.conserv.io/knowledge/scs-1-2-specifications?hsLang=en) have both been discontinued and will be phased out as subscriptions renew.

#### TL;DR Facts

- As long as you maintain an active subscription, your sensors will be replaced and recalibrated as needed - think of it as a perpetual warranty.
- We will send you brand new sensors every 3 years. This handles your recalibration issue.
- The sensor includes temperature, relative humidity, illuminance, and movement readings at above average levels of accuracy.
- The battery life is between 36-48 months

#### Physical Specifications

| Size | 3" W x 3" L x 1" H |
| --- | --- |
| Mounting | Mounts with magnets or command strips |
| Notes | Vertical mounting is recommended to minimize dust accumulation on sensing elements |
| Window | Note that old sensors had a domed window which newer sensors no longer have. |

 

 

![55818116-0-Conserv-sensor-rende](https://support.conserv.io/hs-fs/hubfs/55818116-0-Conserv-sensor-rende.png?width=687&name=55818116-0-Conserv-sensor-rende.png)

#### Primary Temperature Sensor Specifications

| Temperature Range | Operating: –40°C to 85°C Functional: –40°C to 125°C |
| --- | --- |
| Temperature Accuracy | ±0.2°C (typical), ±0.4°C (maximum) |
| Repeatability | ±0.1°C |
| Conversion Time | 1 sec |

#### Secondary Temperature Sensor Specifications

| Temperature Range | –55°C to +150°C |
| --- | --- |
| Temperature Accuracy | ±0.1°C (maximum) from –20°C to +50°C ±0.15°C (maximum) from –40°C to +70°C ±0.2°C (maximum) from –40°C to +100°C |
| Standards Compliance | Medical grade, meets s ASTM E1112 and ISO 80601-2-56 |
| Repeatability | ±1 LSB (0.0078°C) |
| Hysteresis | ±2 LSB (0.0156°C) |

#### Relative Humidity Specifications

| RH Range | 0% to 100% (non-condensing) |
| --- | --- |
| RH Accuracy | ±2% (typical), ±3% (maximum) |
| RH Repeatability | ±0.1% |
| Hysteresis | ±1% |
| Response Time | 8 sec |
| Long Term Drift | ±0.25% / Year |

**Warning:** While the sensor may be both operational and functional at very low (freezing) temperatures, please be aware that this sensor is **not waterproof** and it has not been designed to withstand condensation. Condensation caused by taking the sensor in and out of freezing conditions may damage the internal components. If you wish to use a sensor designed for freezer conditions, we suggest you look into our cold sensor instead.

#### Visible Light Specifications

| Resolution | \< 100 mlx |
| --- | --- |
| Maximum Dynamic Range | 64 klx |

 

![](https://support.conserv.io/hubfs/image-4.png)

#### Movement Specifications

| Measurement Type | Threshold based alerting |
| --- | --- |
| Axis | 3 axis (X,Y,Z) |
| Bias Calibration | Automatic on startup |

#### Network Specifications

| Network Type | LoRaWAN 1.0.2 |
| --- | --- |
| Encryption | AES128 |
| Maximum Output Power | 28mW |
| Operating Frequency | US ISM 915mhz |
| Operating voltage | 3.6v |

#### Battery Specifications

| Battery type | LiSOC2 Lithium, AA size |
| --- | --- |
| Typical Battery Life | 36-48 months |
| Battery voltage | 3.6v |
| Battery capacity | 2x 2400mAh, total 4800mAh |
| Average sleep power consumption | 50uA |
| Configuration mode power consumption | 8mA |
| Average transmission power consumption | 2.5mA |

 

You can read more detail about our battery life specifications, [https://support.conserv.io/knowledge/battery-life-spec](https://support.conserv.io/knowledge/battery-life-spec?hsLang=en)

 

- [Introduction](https://support.conserv.io/knowledge/introduction?hsLang=en)
- [Technical Details and Specifications](https://support.conserv.io/knowledge/technical-details-and-specifications?hsLang=en#main-content)

    - [Sensor Specifications](https://support.conserv.io/knowledge/technical-details-and-specifications?hsLang=en#sensor-specifications)
    - [Other Sensor Information](https://support.conserv.io/knowledge/technical-details-and-specifications?hsLang=en#other-sensor-information)
    - [Gateway Specifications](https://support.conserv.io/knowledge/technical-details-and-specifications?hsLang=en#gateway-specifications)
    - [Conserv Cloud Specifications](https://support.conserv.io/knowledge/technical-details-and-specifications?hsLang=en#conserv-cloud-specifications)
- [Installation and Setup](https://support.conserv.io/knowledge/installation-and-setup?hsLang=en#main-content)

    - [Initial Setup](https://support.conserv.io/knowledge/installation-and-setup?hsLang=en#initial-setup)
    - [Add, Move, Swap and Merge Sensors](https://support.conserv.io/knowledge/installation-and-setup?hsLang=en#add-move-swap-and-merge-sensors)
- [Configure Conserv Cloud](https://support.conserv.io/knowledge/configure-conserv-cloud?hsLang=en#main-content)

    - [Organize and Manage Locations and Spaces](https://support.conserv.io/knowledge/configure-conserv-cloud?hsLang=en#organize-and-manage-locations-and-spaces)
    - [Import Data](https://support.conserv.io/knowledge/configure-conserv-cloud?hsLang=en#import-data)
    - [Configure Levels](https://support.conserv.io/knowledge/configure-conserv-cloud?hsLang=en#configure-levels)
    - [Configure Events and Alerts](https://support.conserv.io/knowledge/configure-conserv-cloud?hsLang=en#configure-events-and-alerts)
- [Profile and Account Management](https://support.conserv.io/knowledge/profile-and-account-management?hsLang=en)
- [Manage Sensors](https://support.conserv.io/knowledge/manage-sensors?hsLang=en)
- [Integrated Pest Management](https://support.conserv.io/knowledge/integrated-pest-management?hsLang=en)
- [Analytics and Reports](https://support.conserv.io/knowledge/analytics-and-reports?hsLang=en#main-content)

    - [Manage Analytics Data](https://support.conserv.io/knowledge/analytics-and-reports?hsLang=en#manage-analytics-data)
    - [Preservation Metrics](https://support.conserv.io/knowledge/analytics-and-reports?hsLang=en#preservation-metrics)
    - [Reports](https://support.conserv.io/knowledge/analytics-and-reports?hsLang=en#reports)
- [Mobile app](https://support.conserv.io/knowledge/mobile-app?hsLang=en)
- [Troubleshooting](https://support.conserv.io/knowledge/troubleshooting?hsLang=en#main-content)

    - [Troubleshoot Conserv Cloud Issues](https://support.conserv.io/knowledge/troubleshooting?hsLang=en#troubleshoot-conserv-cloud-issues)
    - [Troubleshoot Sensor Issues](https://support.conserv.io/knowledge/troubleshooting?hsLang=en#troubleshoot-sensor-issues)
    - [Troubleshoot Gateway Issues](https://support.conserv.io/knowledge/troubleshooting?hsLang=en#troubleshoot-gateway-issues)
    - [Troubleshoot Conserv Cloud Mobile App Issues](https://support.conserv.io/knowledge/troubleshooting?hsLang=en#troubleshoot-conserv-cloud-mobile-app-issues)
- [Community, Support, and Updates](https://support.conserv.io/knowledge/community-support-and-updates?hsLang=en)

- [Support](https://support.conserv.io/knowledge)
- [Blog](https://support.conserv.io/blog)

[![Chill listening crop-3](https://support.conserv.io/hs-fs/hubfs/Cnsrv_wmM_mix_rgb-1.png?width=108&height=24&name=Cnsrv_wmM_mix_rgb-1.png "Chill listening crop-3")](https://conserv.io)

<https://www.linkedin.com/company/teamconserv/>

Copyright © 2026, Conserv Solutions Inc.