Technical details on the Tektelic Tundra Cold Sensor
Table of Contents
- Basic details
- Features
- General System Parameters
- LoRa Parameters
- Regulatory Compliance
- Manufacturer documentation
Basic details
The Tektelic Tundra cold sensor works on the same LoRaWAN network as Conserv's Smart Collection Sensors (SCS). It can be set to report every 15 minutes just like the Conserv SCS.
Image
Features
- Up to 15 Year Battery Life (Dependent on operating temperature and number of readings sent per day)
- 125 Days/3000 Entries of Stored Data
- Optional External Thermistor Probe
- Small Form Factor for Diverse Deployments
- Easily Integrated into LoRaWAN® Networks
- Internal Antenna
- Ambient Tempature & Humidity Monitoring
General System Parameters
Operational Temperature | -40°C to +85°C |
Ingress Protection | IP67 |
Size | 67 x 43 x 36 mm |
Battery | C-Cell lithium battery |
LoRa Parameters
RF Power | Up to 20 dBm |
RF Sensitivity | Up to -137dBm (SF12, 125kHz) |
ISM Band | All Global ISM Bands |
Antenna | Internal |
LoRa Device Class | Class A |
Regulatory Compliance
Safety | IEC 62368-1 (CE) |
Regulatory | ETSI EN 300 220 |
ETSI EN 301-489-1/-3 | |
FCC 15.247 FCC 15.209 | |
RSS-247 RSS-GEN |